HP 70004A PDF

Find great deals for HP a Spectrum Analyzer Display Mainframe W/ HP b Pattern Generator. Shop with confidence on eBay!. Find great deals for Hewlett Packard HP a Display With b Optical Spectrum Analyzer. Shop with confidence on eBay!. Software and documentation supplied. This service guide is part of an Option OB3 package which includes: HP A Service Guide. HP A Component.

Author: Tegul Voodoogul
Country: Sudan
Language: English (Spanish)
Genre: Medical
Published (Last): 15 February 2016
Pages: 376
PDF File Size: 1.81 Mb
ePub File Size: 6.32 Mb
ISBN: 851-6-63346-650-2
Downloads: 9090
Price: Free* [*Free Regsitration Required]
Uploader: Dagor

You can see the power supply slowly increasing the current at turn on until it gets too high before it starts regulating the voltage, and quits. You’ll probably want to use an isolation transformer and differential probes, and keep one hand on your pocket at all times.

This paid for itself in just this repair. I confessed before that I killed a few components on the process, and I could not find replacements for some of them: This last one required some improvisation because it is a quad-transistor instead of dual, and the DIP package is very different.

One day, it refused to turn on.

HP 70004a Spectrum Analyzer Display Mainframe W/ HP 70841b Pattern Generator

After many hours of testing and probing, and and few components that exploded in the process most times my fault I found there was a transformer with a 14 ohm leak between primary and h. I was happy to find it actually worked Do you see that suspicious potting that squeezed outside the can in one of them?:. The block diagram was invaluable, this switching power supplies are complex. Knowing I had nothing to loose, I went and opened the transformer can with a Dremel, and removed the resin with 70004z air and tweezers, carefully to not damage the windings.

  BRIDGES4KIDS ORG IEP IEP GOAL BANK PDF

I could see the power LED flash briefly upon turn-on and then And a final picture of the twin transformers in the working power supply. This board is a latter revision than the ones that appear on the schematics but there are not many changes.

I did not know where to start.

70004A Color System Display

I used a thin teflon tube and 7004a copper wire to recreate the four turns that form the secondary and guess what, it worked!! Can you tell one from the other?

This is the beast on the bench, that PCB looks very timidating to me. You really need to know what you are doing before probing and testing a thing like this live. Home Projects Music Photo. Could this be fixed?

There is a current sense resistor and this is what current looked at turn-on try:. No surpise, the secondary jacket was burned and touching the primary in one spot:. I built this “adapter” thing as a temporary solution, you too know what that means: Many suggested changing every capacitor in the board, something I was not going to do, I wanted to find what the fault really was all capacitors turned to be ok:.

  BLEAK MIDWINTER DARKE PDF

I was lucky to have bought a FLUKE D differential voltage probe this year at Friedrichshafen to the nice guy with grey hair and glasses that sells mostly Fluke stuff.

Keysight Technologies (Agilent HP) A used or new for sale at used-line

Something was drawing more current than expected and the current-limit protection was tripping. I bought this cheap A color display as faulty.

There is no way to check one of the blocks of the power supply alone, you have to give it power and hope for the best. The supply operates a high switching frequency and many parts of the circuit are shorted at DC, so I could not find this until I took both transformers out. High voltage, big and the troubleshooting will need to be done live.